Title | PV | Description |
---|---|---|
Sweep start | :SEQ:n:START_FREQ_S | This sets the initial frequency for the swept NCO. All frequencies are in multiples of the machine revolution frequency. The super sequencer offset is added to the sweep frequency. |
Sweep step | :SEQ:n:STEP_FREQ_S | This sets the frequency advance when the sequencer steps from one dwell period to the next. |
Sweep end | :SEQ:n:END_FREQ_S | This is automatically set to start+step*capture, and is automatically updated any time any of those values changes. If this PV is written to then step will be computed (as (end-start)/capture) and this PV will update. |
Capture | :SEQ:n:COUNT_S | This configures the number of dwells in this sequencer state. |
Holdoff (state) | :SEQ:n:STATE_HOLDOFF_S | This number of turns is added to the start of this sequencer state after the initial sweep frequency has been configured. The detector is disabled for the duration of this holdoff period. |
Holdoff (dwell) | :SEQ:n:HOLDOFF_S | This number of turns is added to the start of the dwell time after the swept frequency has been stepped. The detector is disabled for the duration of the holdoff period, which can be used to give time for the swept system to settle to the new frequency. |
Dwell time | :SEQ:n:DWELL_S | This configures the number of turns for which the sweep frequency is driven and the detector is operated for a single sample. |
NCO Magnitude | :SEQ:n:GAIN_DB_S, :SEQ:n:ENABLE_S | This determines the gain of the swept NCO excitation in 6dB steps, with 0dB corresponding to full scale DAC excitation. :ENABLE_S must be set to "On" for a signal to be generated. |
Bunch Bank | :SEQ:n:BANK_S | This determines which of the four available bunch configuration banks is selected during the operation of this state. |
Blanking | :SEQ:n:BLANK_S | If this is set to "Blanking" then the detector will be temporarily disabled during the blanking window and the dwell time will be extended. |
Data window | :SEQ:n:ENWIN_S | If this is set to "Windowed" then the detector data will be multiplied by the data window configured in Detector Window Setup. |
Tune PLL | :SEQ:n:TUNE_PLL_S | If this is set to "Follow" then the Tune PLL offset will be continuously added to the sweep NCO frequency. This is designed to allow a swept tune to track dynamic changes in the tune. |
Data capture | :SEQ:n:CAPTURE_S | This determines whether the detector is active during this sequencer state. |
...