This group includes the readback waveform at the top.

NamePVDescription
Tune Following Frequency:PLL:NCO:OFFSETWFThis waveform records the complete history of the Tune PLL offset frequency
Offset FIFO readout overrun:PLL:NCO:FIFO_OVFThis will report an alarm status if the OFFSETWF waveform overruns.  Typically this can happen if the detector dwell time is set too low.
Reset FIFO:PLL:NCO:RESET_FIFO_SThis will force the OFFSETWF to discard any partially captured data.  This is used to ensure that the next update received for MEAN_OFFSET is fully up to date.
Freq:PLL:NCO:FREQ_SWhen written this will set the PLL NCO to the given frequency.  If feedback is running the offset will briefly be forced to zero.

:PLL:NCO:FREQThis reads back the current NCO frequency.  This PV updates at 10Hz.
Gain:PLL:NCO:GAIN_SThe NCO signal strength is configured here.

:PLL:NCO:ENABLE_SThis PV turns the NCO output on or off.
Tune:PLL:NCO:TUNEThis is the fractional tune computed from the MEAN_OFFSET value and the base frequency.  This PV updates when MEAN_OFFSET updates, and is forced to NaN when feedback is not running.
Offset:PLL:NCO:OFFSETThis is the current PLL offset, updated at 10Hz.
Mean:PLL:NCO:MEAN_OFFSETThis is the mean offset computed over the last full OFFSETWF waveform.

Detector

Readbacks

Status

Config

Control