NamePVDescription
Freq:PLL:NCO:FREQ_SWhen written this will set the PLL NCO to the given frequency.  If feedback is running the offset will briefly be forced to zero.

:PLL:NCO:FREQThis reads back the current NCO frequency.  This PV updates at 10Hz.
Offset:PLL:NCO:OFFSETThis is the current PLL offset, updated at 10Hz.
Gain:PLL:NCO:GAIN_DB_SThe NCO signal strength is configured here.   Clicking here links to NCO Gain Configuration.

:PLL:NCO:ENABLE_SThis PV turns the NCO output on or off.
Mean:PLL:NCO:MEAN_OFFSETThis is the mean offset computed over the last full OFFSETWF waveform.
Std:PLL:NCO:STD_OFFSETThis is the standard deviation computed over the last full OFFSETWF waveform.
Tune:PLL:NCO:TUNEThis is the fractional tune computed from the MEAN_OFFSET value and the base frequency.  This PV updates when MEAN_OFFSET updates, and is forced to NaN when feedback is not running.

...