Summary
VoCentering | |||||
Process category | Brief description | Computational demand for typical tomography dataset (low, medium, high) | Comment(s) | Reference(s) | Common alternative process(es) |
---|---|---|---|---|---|
filter | To find an optimal value of CoR automatically. | High | Since the computational cost of this auto-centring process is high, it is normally applied to a small, representative subset of data (this can most conveniently be done using the preview parameter of this process). | Reliable method for calculating the center of rotation in parallel-beam tomography | VoCenteringIterative |
Parameters
Savu Configurator command
>>> disp -avv ------------------------------------------------------------------------------------- 1) VoCentering(savu.plugins.centering.vo_centering) A plugin to find the center of rotation per frame 1) preview : [] A slice list of required frames (sinograms) to use in the calulation of the centre of rotation (this will not reduce the data size for subsequent plugins). 2) start_pixel : None The approximate centre. If value is None, take the value from .nxs file else set to image centre. 3) search_area : (-50, 50) Search area from horizontal approximate centre of the image. 4) in_datasets : [] Create a list of the dataset(s) to process. 5) search_radius : 6 Use for fine searching. 6) ratio : 0.5 The ratio between the size of object and FOV of the camera. 7) out_datasets : ['cor_raw', 'cor_fit'] The default names. 8) datasets_to_populate : [] A list of datasets which require this information. 9) row_drop : 20 Drop lines around vertical center of the mask. 10) step : 0.5 Step of fine searching. ------------------------------------------------------------------------------------- >>>
Item | Parameter name | Parameter format | Example(s) | Comment(s) | |
---|---|---|---|---|---|
Parameter value | Effect | ||||
1 | preview | Note that the preview parameter has a nested-cumulative behaviour, i. e. if one specifies VoCentering's preview parameter together with NxtomoLoader's preview parameter, then VoCentering will effectively be selecting a subset from NxtomoLoader's own subset (rather than the entire dataset). Note also that, in this situation, the indices to be supplied for selecting slices for VoCentering must be specified relative to NxtomoLoader's subset (rather than the entire dataset). For instance, one must set VoCentering's preview parameter to [:, 0, :] in order to select the first tomographic slice of any dataset previously loaded by NxtomoLoader, which may, for example, be of the form [:, 123:456, :]. | |||
2 | start_pixel | An initial estimate for the pixel coordinate of an optimal CoR. | |||
3 | search_area | If the value of the search_area parameter is set to the default interval of (-50, 50), then VoCentering will attempt to search for an optimal value of CoR in the (start_pixel - 50, start_pixel + 50) interval. For some datasets, this default range of search (100 pixel) may be not sufficiently large to include an optimal value of CoR, leading to subsequent sub-optimal reconstruction. Therefore, if the value of CoR determined by VoCentering is found to coincide with one of the search-interval limits (i. e. either start_pixel - 50 or start_pixel + 50), then this value of CoR may not necessarily be optimal, and one should re-run VoCentering with a larger value of the search_area parameter to confirm this result. | |||
4 | in_datasets | ||||
5 | search_radius | ||||
6 | ratio | ||||
7 | out_datasets | ||||
8 | datasets_to_populate | ||||
9 | row_drop | ||||
10 | step | Floating-point or integer value in pixel units. |
Usage
TBC.