Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Step 3 - Fitting the Function To the Series

Switch to the Processing Perspective, and load the combined file. In the dialog that appears, select to processing the combined data (/entry/data/data [8,3001]), as a Line (the Column_1 and Temperature axes should be picked up automatically).

Image Added

Once loaded, the first pattern should be shown in the Input view. Click in the Processing view table and add Fit Imported Function (typing fit should filter out the other processing steps). In the Model view table, click in the Value column next to Function File, and file browser to select the saved function file created earlier. Click back on the Fit Imported Function entry to update it with the new path. When the process runs, the data should be visible in the Output view, with the fitted function and residual traces.

Image Added

Pressing the green play button at the top of the Data Slice View, will process all the data, saving the output parameters out into a Nexus file.