Bunch Phase
Measurement of bunch phase for LMBF mode. This shows the magnitude and phase of each bunch using the dual ADC inputs I and Q. This is only available in LMBF mode.
All PVs described here are prefixed with $(device):$(axis01)
, where $(axis01)
is normally IQ
.
Title | PV | Description |
---|---|---|
Bunch Magnitude | :ADC:MAGNITUDE | Magnitude of signal from each bunch, computed as the magnitude of the I and Q ADC signals. |
Bunch Phase | :ADC:PHASE | For bunches with relative magnitude greater than the threshold, shows the bunch phase (relative to Q = 0°), for smaller bunches shows 0. |
Mean magnitude | :ADC:MAGNITUDE_MEAN | Overall average of the bunch magnitudes. |
Mean phase | :ADC:PHASE_MEAN | Phase of the bunch ensemble for bunches with relative magnitude greater than threshold. |
Threshold | :ADC:THRESHOLD | Absolute magnitude threshold, the phases of bunches lower than this magnitude are ignored. Used to detect filled bunches. |